Please, refer to the following table when you are planning on using an External meter as the ones named below are the ones recommended by our team.
External meter | EASTRON SDM 120CT | EASTRON SDM 630 MCT V1 |
Max. Direct Current Measurement (A) | 1-9999A (with CT) | 1-9999A (with CT) |
Direct Voltage Measurement Between Phases | 120-230V | 50-950V / 50-550V |
Direct Measurement Between Phase and Neutral | 120-230V | 20-550V |
Accuracy Class | ||
Active Power | Class 1 | Class 1 |
Reactive Power | Class 2 | Class 2 |
Power Supply | ||
Power Consumption | ≤2W/10VA | ≤2W/10VA |
AC Power Supply Input Voltage | 120-230V | 85-275V / 120-380V |
AC Power Supply Input Frequency | 50/60Hz ±2% | 50/60Hz ±2% |
Generation Specifications | ||
Dimensions (L/H/W) mm | 62x119x17,5 | 72x119x17,5 |
Weight (kg) | 0,1 | 0,29 |
Mounting Options | DIN Rail | DIN Rail |
Degree of Protection | IP51 | IP51 |
Display | LCD | LCD |
Communication Interface | RS485 | RS485 |
Max. Number of Devices to Connect | 32 | 32 |
Regulated Working Temperature Range | (-25+55)ºC | (-25+55)ºC |
CT Clamp | 120A/40mA | 150A/1A |
Humidity | 0-95%, Non-Condensing | 0-95%, Non-Condensing |
Take in consideration the following information:
- Eastron SDM 120 CT are for single phase inverters.
- Eastron SDM 630 MCT V1 are for both, single phase and three phase inverters.
- When using three single phase inverters on a three phase system you need to use the Eastron SDM 630 MCT V2 and connect each CT to the meter and the RJ45 to the master inverter as if it were a normal three phase inverter.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article