Inverter Settings
Set the battery type to “Lithium” and ensure the battery capacity corresponds to the number of Sunsynk batteries used x 100 Ah (5kW Batteries, bigger batteries will be more than 100A). Also check the “Max A Charge” and “Max A Discharge” are set to the number of Sunsynk batteries used x 50 A (for 5kW 0.5C Batteries, other batteries may vary). Depending on the inverter and number of batteries used, sometimes only a lower number may be entered for the charge / discharge current, this is a limitation of the inverter and not an issue. Ensure “Activate Battery” is checked.
Inverter Model | AC Phases | AC Power Cont. | Max Charge/Discharge Current | Recommended Battery Qty. |
---|---|---|---|---|
SUN -3.6K-SG01LP1 SUN -3.6K-SG03LP1 SUN -3.6K-SG04LP1 SUN -3.6K-SG05LP1 | 1 | 3600W | 90A | 2 |
SUN -5K-SG01LP1 SUN -5K-SG03LP1 SUN -5K-SG04LP1 SUN -5K-SG05LP1 | 1 | 5000W | 120A | 3 |
SUN -6K-SG01LP1 SUN -6K-SG03LP1 SUN -6K-SG04LP1 SUN -6K-SG05LP1 | 1 | 6000W | 135A | 3 |
SUN -7.6K-SG01LP1 | 1 | 7600W | 190A | 4 |
SUN -8K-SG01LP1 SUN -8K-SG03LP1 SUN -8K-SG05LP1 | 1 | 8000W | 190A | 4 |
SUN -8K-SG01LP3 | 3 | 8000W | 190A | 4 |
SUN -10K-SG01LP3 | 3 | 10000W | 210A | 4 |
SUN -12K-SG01LP3 | 3 | 12000W | 240A | 5 |